✔ Components approved for the ATEX area
✔ High level of quality
✔ Delivery with ATEX-compliant documentation
ATEX doors und fire protection sliding doors work even, when it gets dangerous! The use of doors and gates in potentially explosive areas, such as warehouses for gas and solvents or silos, places special demands on safety. For the European Union, these requirements are regulated in the ATEX product directive. These include elements in stainless steel design, electrostatic conductivity or the thinnest possible coating thickness of max. 0.2 mm.All common Teckentrup doors as well as the fire protection sliding doors „T30/90 Teckentrup 72 E“ are optionally available with explosion protection in accordance with the ATEX directive. Doors and gates for EX-protection convince by quick assembly and flexible solutions. In combination with our additional equipment, our products offer safety wherever it is particularly important.
Strong design
• Stainless steel version
• Single and double-doors
• Individual design possibilities1)
• RAL of choice
• Optionally with glazing
Strong safety
• Additional equipment for safety, fire and smoke protection
• New mechanical triple locks as an alternative
• Implementation according to ATEX directive 2014/34/EU
Strong service
• Comprehensive object and product advice
• Modular configuration
1) Thin fold 42 mm and 62 mm, thick fold 62mm
Additional options for components
• Electric door opener
• Hold-open device
• Magnetic lock
• Selflocking paniclock(SVP)
• Retractable bottom seal
• 3D-hinges made of stainless steel
• Glazing (only with steel glazing bead)
Protection zones
Doors can be used in the following zones2)
• Gas zones 1 and 2
• Dust zones 21 and 22
2) The zones defined in the ATEX directive describe the type and duration
of presence of explosive atmospheres.
*with additional equipment
Strong design
• RAL of choice
• With wicket door and glazing
Strong safety
• Fire-resistant and smoke-proof tested
• Inclination and gradient in the door opening area can be
compensated by the adjustable floor profile
• Implementation according to ATEX Directive 2014/34/EU
Strong service
• Comprehensive object and product advice
Additional options for components
• Hold-open device1)
• Magnetic lock
• Selflocking paniclock (wicket door)
• Retractable bottom seal
• 3D-hinges made of stainless steel
• Glazing (only with steel glazing bead)
1) Acceptance/ commissioning by Hekatron
Proctection zones
Doors can be used in the following zones2)
• Gas zones 1 and 2
• Dust zones 21 and 22
2) The zones defined in the ATEX directive describe the type and
duration of presence of explosive atmospheres.
* with additional equipment